generator dealers in chennai

Diesel Generator Applications & Uses for Industries

A diesel generator is used for emergency power supply in case of electricity shutdown or places where there power supply demand. Diesel generator generates electric energy by using a diesel engine along with an electric generator.

Nowadays, diesel generator usage is essential for industries backup, emergency, and electric systems in case of power failure. Hiring diesel generators for monitor electric current continuously and automatically start the generator when there is a power cut or power shutdown period and generator supply the power until the power comes back.

The diesel generator is the most important equipment for industries and helps to run the industries’ productions continuously. The favorable growth of industries such as oil & gas industries, telecom, mining, constructions, hospitals, and retail shops.

Diesel Generator Usage for Following Industries Below:

Mining

In all over the world running mining operation so diesel generator widely used for mining operations. They needed 80% of the power supply for mining operations because they are having heavy-duty equipment such as excavating machinery, drillers, conveyor belts, and cranes. Mining operations mainly used to get gas, coal, iron, and metals being mined. So, diesel generators are used always and number one option for easily used far-fetched mining zones with very extreme situations.

mining

Healthcare

Healthcare is one of the most sensitive industries. Hospitals have a lot of medical facilities for patients and also have diesel generators facility for emergencies. If not have generators facilities in hospitals many patients lose their lives in case of power failure or interruption of electricity.

Patients are seriously ill and injured such as those patients in an intensive care unit (ICU) it would be at risk because life with the support of machines like oxygen pumps would fail to function with the slightest power outage and also used ventilators in ICU that helps to breathe when patients are in sick, injured or sedated for an operation.

In hospitals, diesel generators are widely used for backup power sources and provide uninterrupted power supply when the utility power grid fails. All-time maintain a full tank of diesel can last an entire hospital more than 8 hours depending on its size and compare to other generators, diesel generators can provide the backup power source for more than 48 hours. It depends on fuel storage.

Commercial

In the commercial industry without a power backup plan lose money in business. Power Failure can make this thorn in the flesh. Commercial industries without investing the cost in standby diesel generator, losses huge revenue at the case register, safety challenges for both people and finances, trouble for IT industries, and other automated equipment finally complete operations shutdown. So, diesel generators allow you to protect your business interests & revenues.

Oil & Gas

Diesel generators are mandatory usage for the oil & gas industry because diesel generator is an integral part of this industry all activities are based on gas fields including drilling, pumping, and loading. In most cases oil and gas exploration works remote locations with tough conditions. So, without diesel generator on-site would be quite impossible because most of the sites away from power grids. Only diesel generators fit for this site.

oil & gas industry

Manufacturing

Manufacturing industries can always need high volume productions. Sometimes slight disruption in manufacturing industries can not only low volume production and also not poor quality production. The low volume of production and low quality of the product depends on power supply interruption. The production line in the manufacturing line must be operating all the time. If blackouts occur in 24/7 manufacturing plants, then affect all the processes and affected the product quality. A diesel generator provides emergency power supply in case of blackouts and helps to prevent losses of production.

Construction

Generators will give power source support for constructions 24/7. Diesel generator helps power backup support for all construction equipments like power air conditioning, machines, power communication system, and run construction equipment such as cranes. Impossible for without power grid support for all construction sites only a few more construction sites have a power grid. If construction sites faced constant power interruptions can result in project completion time delayed due to power backup issue.

Telecommunication and Data Centers

Electronic machines, Computers, and data centers are the heart of every industry. Banks, IT industries, government sectors, railway, airways, and many industries have their own data stored servers. 

Manual and cloud servers using to access data at all times for their business to operate without interruption of power supply. With constant power supply issues or power interruptions, these servers unable access and business have to halt their operations. Losing business and money in the process.

 Diesel generators have provided very reliable service to telecommunication and data center industries after an interrupt in power backup or power grid failure, Automatically started and run the diesel generator.

Utilities

Sometimes Power generation plants also need generators due to emergencies. So, Power suppliers that depend on diesel generators for power productions run without interruption. Power generation plants have diesel generator standing for the main supply line emergency. They use diesel generators to produce enough electricity to power thousands of homes until they recover the main supply issue resolve. 

Diesel generators help this industry allow power plant crew adequate time to work the main supply. Finally diesel generator helps to prevent the power supply problem in power generation plants.

Manual and cloud servers using to access data at all times for their business to operate without interruption of power supply. With constant power supply issues or power interruptions, these servers unable access and business have to halt their operations. Losing business and money in the process.

Diesel generators have provided very reliable service to telecommunication and data center industries after an interrupt in power backup or power grid failure, Automatically started and run the diesel generator.

Education

Nowadays, All schools, colleges, and other educational institutes of higher learning required generators. Several systems in the education system mandatory need for electricity. Causes of power outages are a lot more than students getting the rest of the day off. So, better institutes hire generators to resolve power interruption or power cut problems and serve continuous high-quality education for students. Educational institutes without power cannot provide the kind of safety they need to ensure.

schools

Military

This industry is heavily dependent on diesel generators. Soldiers need all time good and stable power sources that can be carried the toughest environments and still function efficiently. So, the military use diesel generators for a wide range of applications including a power supply for their gear, hospitals, lighting for the training camps and Operating the IT equipment.

BUY A DIESEL GENERATOR OR HIRE A RENTAL GENERATOR. WE SUPPLY YOU WITH THE POWER YOU NEED WHEN YOU NEED IT
8 Important Steps For Proper Maintenance Of Diesel Generators

8 Important Steps For Proper Maintenance of Diesel Generators

A Diesel generator is processing the electric generator to generate electrical energy. This is the specific case of the engine generator. A diesel compression-ignition engine often is designed to run fuel oil also some types are adapted to run with liquid fuels or natural gas.

Generator Users require less maintenance due to their durability (it means measures the length of product life), reliability (it means the product will not fail within a specific period of time), and the sturdiness characteristic (It means the durability of the product), and also they are considered cheaper to operate due to the low fuels costs as compared to the other types of fuels such as gasoline and propane. When you reach the best generator dealers they’ll guide you.

Shaktiman Diesel Generator

Diesel Generator

Every Business needs a Standby Diesel generator For Backup Power and the Generator Gives More power to the whole Unit. Also considered to withstand heavy loads for long hours and start off the power supply on the full load within minutes and must be regularly maintained to ensure they provide quality power throughout their service life.

The best diesel generator maintenance practice is following the maintenance schedule provided by the generator manufacturer to ensure maximum service time for the generator and proper operation when it is called upon to provide power.

The engine is the core component of the generator. If you want to run your generator well without any mechanical issues or electrical issues must maintain the generators carefully.

Once you start running the diesel generator, the exhaust system, fuel system, DC electrical system, and engine require close monitoring for any leaks that can cause hazardous occurrences. The very essential one is to maintain the internal combustion engine. A backup generator is mandatory in the industry and also proper maintenance of diesel generators is important so take a look at these steps.

Step 1: Lubrication Service

The Engine oil must be checked while powering off the generator at regular intervals using a dipstick.

Allow the oil in the upper portion of the engine to drain back into the crankcase and follow the engine manufacturer’s recommendations for API oil classification and oil viscosity.

Keep watching the oil level as near as possible to the full mark on the dipstick by adding the same quality and brand of oil. The oil and filter must also be changed at particular time intervals. Check regularly with the engine manufacturer for procedures for draining the oil and replacing the oil filter and their disposal is to be done appropriately to avoid environmental damage or liability.

Step 2: Cooling System

Check the coolant oil level during shutdown periods at the specified interval.

Must be noted these points “remove the radiator cap after allowing the engine to cool, and, if necessary, add coolant until the level is about 3/4 in” And a More critical role in balancing diesel engines require a balanced coolant mixture of water, antifreeze, and coolant additives.

Examine the exterior of the radiator for obstructions, and remove all dirt, grimy or foreign material with a soft brush or cloth with caution to avoid damaging the fins.

If available means, use the low-pressure compressed air or a stream of water in the opposite direction of normal airflow to clean the radiator.

WARNING
Please don’t remove the pressure cap from a hot engine. Wait until the coolant temperature is below 120°F (50°C) before removing the pressure cap. Because heated coolant spray or steam can cause injury.

Step 3: Fuel System

This is the important point when it comes to the maintenance of diesel generators. Diesel is subject to contamination and corrosion within a period of time is one year, and therefore regular generator set exercise is highly recommended to use up stored fuel before it degrades.

The fuel filters should be drained at the designated intervals due to the water vapor that accumulates and condenses in the fuel tank.

Better check regularly testing and fuel polishing may be required if the fuel is not used and replaced in three to six months.

Step 4: Testing Batteries

If the battery’s charges reach the dead-end level is a common cause of standby power system failures.

The battery must be kept fully charged and well-maintained at an all-time 40% to 100% to avoid regular testing and inspection to know the current status of the battery and avoid low battery levels.

Batteries check

Do you want to increase battery performance?

Must be cleaned, and the specific gravity and electrolyte levels of the battery checked frequently.

  • Testing batteries
  • Cleaning batteries
  • Checking specific gravity
  • Checking electrolyte level

Step 5: Routine Engine Exercise

Regular exercising keeps the engine parts lubricated and thwarts oxidation of electrical contacts, uses up the fuel before it deteriorates, and helps to provide diesel generator maintenance to reliable engine starting.

Engine exercise is recommended to be executed 15 days once or 25 days once for a minimum of 30 min

Step 6: Keep your Diesel Generator Clean

Maintain your engine all-time nice and clean because it will be taken care of Oil drips and other issues. Check day-by-day hoses and belts that are in good condition or not.

Frequent checks can keep better conditions and other nuisances from nesting in your equipment. However, the generator users thought is a generator set that is rarely used and might not need a lot of care. So, please avoid this kind of thought and keeps regular maintenance of diesel generators based on manufacturer guidelines.

Keep Diesel engine clean

Step 7: Exhaust system inspection

In case of any leaks along the exhaust line which usually occur at the connection points, the welds, and the gaskets. Find the place of leakages and repair them immediately by a technician.

Step 8: Operating Inspections

When the Diesel Generator is Running these Guidelines Should Be inspected in operation inspection.

Common Manufacturer Inspections guidelines for diesel generators are below,

  • Disconnect generator batteries.
  • Drain the fuel system and change fuel filters.
  • Drain coolant and change coolant filters.
  • Replace air filters.
  • Cover all intake and exhaust ports.
  • Disconnect all generator supply connections.

So this is the important point for Diesel generator Maintenance and mainly you want to take a look at the specification of diesel generators. 

If you need more details? Contact Us Today!

About Us

Shaktiman Equipments Pvt Ltd (formerly known as Pioneer Generator Pvt Ltd is one of India’s leading energy & Air engineering solutions company). It has a presence across a wide range of businesses as a Distributorship for Air compressor sales, service of ELGI Equipments Ltd, and Original Equipment manufacturer of Diesel Generator for Tamilnadu & Pondicherry. Additionally, the company offers Rental services for all its products, including Godrej Forklifts and Smarta [MLT].

Get Daily Updates

Shaktiman Equipments Pvt Ltd.

Address : No.9, Vellalar Street, School Road, East Ayanambakkam, Chennai – 600 095.
Phone: 044- 24420592
Mobile:  +91 9940-577-409
Email: info@shaktiman.co

Pioneer Ecorp Logo White
Branding & Digital Marketing by  Pioneer Ecorp

Shaktiman Equipments Pvt Ltd | Copyright © 2025. All Rights Reserved. | Privacy Policy

Call Now